680340 to 680342(H) - PSTN-1 line settings
680340
Bits 0 and 1: PSTN access method from behind a PABX.
Bit
1
0
0
0
0
1
1
0
1
1
Bit 2: Telephone line type.
0: PSTN, 1: PABX
Bits 3 and 4: Dialing type.
Bit
4
3
0
0
0
1
1
0
1
1
Bits 4 to 7: Not used
680341: PSTN access number for loop start
Access number Hex value to program (BCD)
0
9
00
99
680342
Bit 0: Transmission disabled
0: Tx and Rx, 1: Rx only
Bit 1: Memory Lock reception
0: Enabled, 1: Disabled
Bits 2 to 7: Not used
680360(H) – Polling ID Code (Low – Hex)
680361(H) – Polling ID Code (High – Hex)
680362(H) - Confidential ID (low - BCD)
680363(H) - Confidential ID (high - BCD)
680364(H) - Memory Lock ID (low - BCD)
680365(H) - Memory Lock ID (high - BCD)
SM
CÓPIA NÃO CONTROLADA
Setting
Loop start
Ground start
Flash start
Not used
Setting
Pulse dialing
Not used
Tone dialing
Not used
F0
F9
00
99
67
CÓPIA NÃO CONTROLADA
SERVICE RAM ADDRESSES
Fax Unit

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044