Installation Requirements; Environment - Gestetner B130 Service Manual

Table of Contents

Advertisement

1. INSTALLATION
CAUTION
Before installing an optional unit, do the following:
1. If there is a fax unit on the machine, print out all messages stored in the
memory, all user-programmed items, and a system parameter list.
2. If there is a printer option on the machine, print out all data in the
printer buffer.
3. Turn off the main switch and disconnect the power cord, the telephone
line, and the network cable.

1.1 INSTALLATION REQUIREMENTS

1.1.1 ENVIRONMENT

Humidity
80%
54%
15%
1. Temperature Range: 10°C to 32°C (50°F to 89.6°F)
2. Humidity Range:
3. Ambient Illumination: Less than 1,500 lux (Do not expose to direct sunlight.)
4. Ventilation:
5. Ambient Dust
6. Do not install the machine where it will be exposed to direct sunlight or to direct
airflow (from a fan, air conditioner, air cleaner, etc.).
7. Do not install the machine where it will be exposed to corrosive gas.
8. Place the machine on a firm and level base.
9. Do not install the machine where it may be subjected to strong vibration.
SM
CÓPIA NÃO CONTROLADA
–Temperature and Humidity Chart–
Operation range
10°C
27°C
(50°F)
(80.6°F)
15% to 80% RH
Room air should turn over at least 3 times/hr/person
Less than 0.1 mg/m
1-1
CÓPIA NÃO CONTROLADA
INSTALLATION REQUIREMENTS
Temperature
32°C
(89.6°F)
B046I512.WMF
3
B129 Series/B044 Series