BIT SWITCHES

5.2
BIT SWITCHES
2
WARNING
Do not adjust a bit switch or use a setting that is described as "Not used",
as this may cause the machine to malfunction or to operate in a manner
that is not accepted by local regulations. Such bits are for use only in other
countries, such as Japan.
NOTE: Default settings for bit switches are not listed in this manual. Refer to the
System Parameter List printed by the machine.

5.1.1 SYSTEM SWITCHES

System Switch 00
No.
RAM Reset
0, 1
Bit 1
0
Reset Level
0
0
No reset
0
1
Reset Level 2
1
0
Reset Level 3
1
1
Not used
B465
CÓPIA NÃO CONTROLADA
FUNCTION
CÓPIA NÃO CONTROLADA
COMMENTS
Reset Level 3: Erases all image data files
stored in the SAF memory and communication
files (e.g. substitute RX files). This is the
recommended setting when the SAF requires
clearing.
Reset Level 2: This level erases the following
items in addition to those erased by Reset
Level 3: own telephone number, bit switches
(excluding country code), RTI/TTI/CSI, report
data, programmed telephone numbers
(Quick/Speed/Groups, service station, etc.),
NCU parameters, and personal codes. The
NCU country code is also set to the same as
the bit switch country code (System Bit Switch
0F).
After erasing, the machine automatically
changes these two bits back to 0.
No reset: Normal operation
Cross-reference
RAM Reset Level 1 (Factory reset):
Change the RAM address data from
400005(H) to FF(H), then turn the machine off
and on. In addition to those items erased by
Reset Level 2, the clock, country code (the
default country code is Japan), scan margin
settings and print registration settings are
erased. To adjust the country code, you must
first set system switch 15 bit 2 to 1.