Fax Sc Codes; Sc1201; Other Sc Codes; Fax Sc Code Table - Gestetner B130 Service Manual

Table of Contents

Advertisement

2.2 FAX SC CODES

2.2.1 SC1201

SC1201 indicates an unrecoverable error. The fax unit does not operate until you
initialize the SRAM. When you initialize it, all user-specified data and SP settings
are lost. There is no way to recover these data. SC1201 can be generated under
any of the following conditions:
• The SRAM backup battery is dead.
• The switch of the SRAM backup battery is open.
• The SRAM on the MBU is physically defective.

2.2.2 OTHER SC CODES

The FCU resets itself automatically by default. The data in the SAF memory is
retained. When you want to prevent this automatic resetting, change Bit 7 of the
System Switch 1F (! 3.2.1). The FCU displays an SC code and does not operate
until you reset it. To reset it, perform as follows (either of them):
• Hold down the  and  keys until the FCU is reset (for about 10 seconds).
• Turn the main power switch off and on.

2.2.3 FAX SC CODE TABLE

The table lists the SC codes generated in the fax unit.
Code
Description
1101
FCU error
1201
Unrecoverable error
1299
Software error
1305
1310
1311
1312
1401
1405
The table lists the SC code generated in the controller of the copier.
Code
Description
820
MBU error (The
jumper is loose.)
SM
CÓPIA NÃO CONTROLADA
Countermeasure
Reset the FCU (! 2.2.2).
Initialize the SRAM (! 2.2.1).
Reset the FCU (! 2.2.2).
Countermeasure
Set the jumper (on
the MBU) correctly.
11
CÓPIA NÃO CONTROLADA
FAX SC CODES
System Switch 1F
and Display
Bit 7 = 0
(None*)
Service Call
(None*)
* Automatically reset
Detailed Code
The following codes are displayed:
• SC:
820
• code: 612
• detail: 40000000
Bit 7 = 1
SC code
Fax Unit