5.3 NCU PARAMETERS
The following tables give the RAM addresses and the parameter calculation units
that the machine uses for ringing signal detection and automatic dialing. The
factory settings for each country are also given. Most of these must be changed by
RAM read/write (Function 06-0), but some can be changed using NCU Parameter
programming (Function 07-0). If Function 07-0 can be used, this will be indicated in
the Remarks column. The RAM is programmed in hex code unless (BCD) is
included in the Unit column.
Address
401400
Country code for NCU parameters
SM
CÓPIA NÃO CONTROLADA
Function
5-33
CÓPIA NÃO CONTROLADA
NCU PARAMETERS
Unit
Remarks
Use the Hex value to program the
country code directly into this address,
or use the decimal value to program it
using Function 07-0 (parameter C.C.).
Note: NA model only
You will have to set system switch 15 bit
2 to 1 before trying to change the NCU
country code.
Country
Decimal
France
00
Germany
01
UK
02
Italy
03
Austria
04
Belgium
05
Denmark
06
Finland
07
Ireland
08
Norway
09
Sweden
10
Switzerland
11
Portugal
12
Holland
13
Spain
14
Israel
15
USA
17
Asia
18
Hong Kong
20
South Africa
21
Australia
22
New Zealand
23
Singapore
24
Malaysia
25
China
26
Formosa
27
Korea
28
Turkey
32
Greece
33
Hungary
34
Czech
35
Poland
36
Hex
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
11
12
14
15
16
17
18
19
1A
1B
1C
20
21
22
23
24
B465