BIT SWITCHES
G3 Switch 06
No.
Function
4–7 Modem types available for
reception
Bit 7 6 5 4
0 0 0 1
0 0 1 0
0 0 1 1
0 1 0 0
0 1 0 1
Other settings - Not used
G3 Switch 07
No.
FUNCTION
0, 1 PSTN cable equalizer
(tx mode: Internal)
Bit 1
Bit 0
0
0
0
1
1
0
1
1
2, 3 PSTN cable equalizer
(rx mode: Internal)
Bit 3
Bit 2
0
0
0
1
1
0
1
1
4
PSTN cable equalizer
(V.27ter, V.29, V.33/V.17, V.8
rx mode: External)
0: Disabled 1: Enabled
5–7 Not used
B465
CÓPIA NÃO CONTROLADA
The setting of these bits is used to inform the
transmitting terminal of the available modem type for
Setting
the machine in receive mode.
V.27ter
V.27ter, V.29
If V.34 is not selected, V.8 protocol must be
Not used
disabled manually.
V.27ter, V.29,
V.17
Cross reference
V.27ter, V.29,
V.8 protocol on/off - G3 switch 03, bit 2
V.17,V.34
Use a higher setting if there is signal loss at higher
frequencies because of the length of wire between
Setting
the modem and the telephone exchange.
None
Use the dedicated transmission parameters for
Low
specific receivers.
Medium
High
Also, try using the cable equalizer if one or more of
the following symptoms occurs.
Communication error
Modem rate fallback occurs frequently.
Note: This setting is not effective in V.34
communications.
Use a higher setting if there is signal loss at higher
frequencies because of the length of wire between
Setting
the modem and the telephone exchange.
None
Low
Also, try using the cable equalizer if one or more of
Medium
the following symptoms occurs.
High
Communication error with error codes such as
Modem rate fallback occurs frequently.
Note: This setting is not effective in V.34
communications.
Keep this bit at "1" in most cases.
Do not change these settings.
5-30