2
Mode Number/Name
906*
Tailing Correction
1
Shift value
2
Interval
908
Forced Toner Supply
1
915*
Polygon Mirror Motor Idling Time
1
922*
Toner Supply Time
1
926*
Standard Vt
1
SM
CÓPIA NÃO CONTROLADA
When printing multiple copies, the machine will shift the
image writing position by the specified amount after every
n copies, where n is given by SP2-906-2.
[0.0 ~ 1.0 / 0.0 / 0.1 mm/step]
When making many copies of an original that contains
vertical lines (such as in tables), the paper may not
separate correctly. This can cause tailing images (ghosts
of the vertical lines continuing past the bottom of the
table). This SP corrects the problem by shifting the paper
after every specified number of copies.
Changes the interval for the image shift specified by SP2-
906-1.
[1 ~ 10 / 1 / 1 page/step]
If the setting is n, the machine executes the shift after the
first n copies, then shifts back to standard position after
the next n copies, and so on.
Forces the toner bottle (or toner hopper) to supply toner to
the toner supply unit. Press "1" to start.
[0 = No / 1 = Yes]
The machine supplies toner over a total of 15 seconds
(1.5 second on, 1.5 second off, repeated 5 times).
Selects the polygon mirror motor idling time.
[0 = None / 1 = 15 s / 2 = 25 s]
To increase the speed of the first copy, the mirror motor
begins idling when the user sets an original, touches a
key, or opens the platen cover or DF. If this setting is left
at the default (25 s), the motor will stop if the user does
nothing for 25 s. If the setting is "0", the motor will not
switch off during standby. (Regardless of the setting, the
motor will switch off when the machine enters low-power
mode.)
Adjusts the toner supply motor ON time.
[0.1 ~ 5.0 / 0.6 / 0.1 s/step]
Raising this value increases the toner supply motor
ON time. Set to a high value if the user tends to make
many copies having high proportions of solid black
image areas.
(
6.12.4, "Toner Density Control")
Adjusts Vts (the reference voltage used for new
developer). The TD sensor output is adjusted to this value
during the TD sensor initial setting process.
[0.00 ~ 3.3 / 1.25 / 0.01 V/step] DFU