BIT SWITCHES
System Switch 10
No
FUNCTION
0
Threshold memory level for
to
parallel memory transmission
7
System Switch 11
No
FUNCTION
0
TTI printing position
0: Superimposed on the page
data
1: Printed before the data
leading edge
1-7
Not used
System Switch 12
No
FUNCTION
0
TTI printing position in the main
to
scan direction
7
System Switch 13 - Not used (Do not change the settings.)
System Switch 14 - Not used (Do not change the settings.)
Fax Unit
CÓPIA NÃO CONTROLADA
Threshold = is N x 128 kbytes + 256 kbytes
N can be between 00 - FF(H)
Default setting: 02(H) = 512 kbytes
Change this bit to 1 if the TTI overprints information
that the customer considers to be important (G3
transmissions).
Do not change the factory settings.
TTI: 08 to 92 (BCD) mm
Input even numbers only.
This setting determines the print start position for
the TTI and CIL from the left edge of the paper. If
the TTI is moved too far to the right, it may overwrite
the file number which is on the top right of the page.
24
CÓPIA NÃO CONTROLADA
COMMENTS
SP No. 1-101-018
COMMENTS
SP No. 1-101-019