No.
Definition
954
B
Printer application program error
The printer application program does
not become ready when the printer
application program is necessary.
955
B
Image transfer error
The BICU requests the controller to
transfer image data; but the controller
does not become ready.
964
B
Status error (laser optics housing unit)
The optics-housing unit does not
become ready within 17 seconds after
a request.
980
B
Controller-engine inconsistency
The controller is incompatible with the
engine.
981
B
NVRAM error
An error occurs during engine NVRAM
check.
982
B
Localization error
The localization information in the
non-volatile ROM and in the NVRAM is
different (
984
B
Print image transfer error
Print images are not transferred.
SM
CÓPIA NÃO CONTROLADA
Symptom
SP5-807-001).
4-9
CÓPIA NÃO CONTROLADA
SERVICE CALL CONDITIONS
Possible Cause
• Defective application program
• Defective application program
• Defective software
• One of the following controllers is
installed to the B129 model:
- The controller of the MFP model
- The controller of the copier/facsimile
model
- The controller of the
printer/scanner/copier model
• The controller of the optional
printer/scanner is installed to one of
the following models:
- The MFP model
- The copier/facsimile model
- The printer/scanner/copier model
• Defective NVRAM
• Loose connection between the BICU
and the NVRAM
• Incorrect installation of the NVRAM
• Defective BICU
• Localization setting not specified (The
main power switch is turned on for the
first time after the NVRAM is
replaced.)
• Incorrect localization setting
• Defective NVRAM
• Defective controller
• Defective BICU
• Loose connection between the
controller and the BICU