Gestetner B130 Service Manual page 607

Table of Contents

Advertisement

BIT SWITCHES
System Switch 11
No.
6
Memory reception if no RTI or CSI
received
0: Reception disabled
1: Reception enabled only when
there is no problem with the
printer mechanism
7
Not used
System Switch 12
No.
0–7
TTI printing position in the main
scan direction
System Switch 13 - Not used (do not change any of these settings)
System Switch 14 - Not used (do not change any of these settings)
System Switch 15
No.
0
Not used
1
Programming with European
characters
0: Disabled 1: Enabled
2
Change NCU country code
0: Disabled 1: Enabled
3
Not used
4
Daylight saving time automatic
adjustment (NA only)
0: Manual adjustment
1: Automatic adjustment
5–7
Not used
System Switch 16 - Not used (do not change any of these settings)
B465
CÓPIA NÃO CONTROLADA
FUNCTION
FUNCTION
FUNCTION
5-14
CÓPIA NÃO CONTROLADA
COMMENTS
This switch setting is dependent on user
parameter switch 05 bit 1.
This Sw
U.P.05 bit 1
--
0 : Reception always enabled
0
1 : Reception disabled
1
1 : Reception enabled only
there is no problem with
the printer mechanism
Do not change the setting.
COMMENTS
08 to 92 (BCD) mm. Only input even numbers.
This setting determines the TTI print start
position from the left edge of the paper. If the
TTI is too far to the right, the file number,
which is on the top right of the page, may
obscure it.
COMMENTS
Do not change this setting.
1: The user can program with European
characters (e.g. "ä", "å") for the TTI, Quick
Dial labels, etc.
0: The machine does not display "c.c." in the
service mode 07: NCU, 0: NCU PARA
menu.
Do not change the setting.
1: The clock is adjusted automatically at start
and end of daylight-saving time (in April and
October).
Do not change these settings.
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044