Gestetner B130 Service Manual page 130

Table of Contents

Advertisement

SERVICE CALL CONDITIONS
No.
Definition
990
B
Unrecoverable software error
A software program performs other
than as expected.
991
D
Recoverable software error
A software program performs other
than as expected; the program can
continue normal processing.
992
B
Unexpected Software Error
An undefined error occurs.
997
C
Application function error
The application program does not
respond or does not start correctly.
998
B
Application start error
No application program starts within 60
seconds after the main power switch is
turned on
999
B
Program download error
An error occurs during program
download from an IC card.
B129 Series/B044 Series
CÓPIA NÃO CONTROLADA
Symptom
4-10
CÓPIA NÃO CONTROLADA
Possible Cause
• Defective firmware
• Incorrect internal parameter
• Insufficient working memory
NOTE: The file name, address, and
data are stored in the NVRAM. You can
view the information (
• Incorrect internal parameter
• Insufficient working memory
• Defective firmware
• Defective firmware
• Defective firmware
• Necessary resource not found
• Incorrect installation of a PCB
• Defective BICU
• Defective controller
• Defective IC card
• Defective NVRAM
• Power failure
NOTE: SC999 is not logged. Once
downloading fails, you may be unable
to retry it. In a case like this, you must
replace the related PCB.
SP7-403).
SM

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044

Table of Contents