Gestetner B130 Service Manual page 214

Table of Contents

Advertisement

5
Mode Number/Name
810
SC Code Reset
811*
Serial Number Input
812*
Service Telephone Number
824
SRAM Data Upload
825
SRAM Data Download
826
Program Upload
827
Program Download
SM
CÓPIA NÃO CONTROLADA
Resets all level-A service call conditions, such as fusing
errors.
[0 = No / 1 = Yes]
After selecting "1", hold down the Original Type key
and press the OK key (or the
reset. If the reset succeeds, the machine reboots. If it
fails, the display shows "Error!!!".
(
4.1, "Service Call Conditions")
Used to input the machine serial number (normally done
at the factory). This is the serial number printed on SMC
reports. (
5.1.10)
Use this to input the telephone number of the service
representative. (This number is displayed when a service
call condition occurs.)
To input a dash, press
Use
to delete the existing phone number or to
delete the last digit that you entered.
Uploads SP and UP settings from the machine's SRAM to
a flash memory card. (
[0 = No / 1 = Yes]
This SP is effective only if a flash memory card has
been plugged into the machine's card slot.
Downloads SP mode data from a flash memory card to
the machine's SRAM. (
[0 = No / 1 = Yes]
This SP is effective only if a flash memory card has
been plugged into the machine's card slot.
Uploads the system program from the machine's SRAM
into the flash memory card plugged into the machine's
card slot. (
5.1.8)
[0 = No / 1 = Yes]
This SP is effective only if a flash memory card has
been plugged into the machine's card slot.
Downloads the system program from a flash memory card
to the machine's SRAM. (
[0 = No / 1 = Download first 2MB / 2= Download last 2MB]
This SP is effective only if you have booted the
machine from a flash memory card.
5-73
CÓPIA NÃO CONTROLADA
SERVICE PROGRAM
Function/[Setting]
key) to execute the
.
5.1.9)
5.1.9)
5.1.8)
B129 Series/B044 Series

Advertisement

Table of Contents
loading

This manual is also suitable for:

B129B045B168B169B046B044

Table of Contents