portCfgShow

Displays port configuration settings.
Synopsis: V3.1.x
portCfgShow [portnumber]
Synopsis: V4.1.x
portCfgShow [slotnumber/][portnumber]
Availability
All users.
Release
V3.1.x and V4.1.x
Description
Use this command to display the current configuration of all ports. If no operand
is specified, all the port configuration settings are displayed for that switch, or for
the StorageWorks Core logical switch.
The following configuration information is displayed:
Fabric OS Version 3.1.x/4.1.x Reference Guide
Port Speed is displayed as 1G, 2G, or AN (when in Auto speed Negotiation
mode). This value is set by the portCfgSpeed command.
Trunk Port is displayed as ON when port is set for trunking or blank (--) when
trunking is disabled on the port. This value is set by the
portCfgTrunkport command.
The Long Distance setting of the port is shown as blank (--) when long
distance mode is off, L1 when the link is up to 50 Km, or L2 when the link is
up to 100 Km. This value is set by the portCfgLongDistance
command.
VC Link Init setting of the port is shown as blank (..) when the long distance
link initialization option is turned off and (ON) when it is turned on for long
distance mode. This value is set by the portcfglongdistance
command.