HP StorageWorks MSA 2/8 - SAN Switch Reference Manual page 137

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Example
To run a CMI test between two ASICs in V3.1.x:
switch:admin> cmiTest
Running CMI Test .............. passed.
To run a CMI test between two ASICs in V4.1.x:
switch:admin> cmitest -txports 1/0-1/7 -rxports 1/8-1/15
Running CMI Test ..............Test Complete: "cmitest" Pass 1 of 1
Duration 0 hr, 0 min & 2 sec (0:0:2:563).
passed.
Errors
When it detects failures, the subtest may report one or more of the following error
messages:
Fabric OS Version 3.1.x/4.1.x Reference Guide
For V3.1.x:
DIAG-CMISA1
DIAG-CMINOCAP
DIAG-CMICKSUM
DIAG-CMIINVCAP
DIAG-CMIDATA
DIAG-INTNIL
DIAG-BADINT
For V4.1.x:
DIAG-BADINT
DIAG-CMICKSUM
DIAG-CMIDATA
DIAG-CMIINVCAP
DIAG-CMINOCAP
DIAG-CMISA1
DIAG-INTNIL
cmiTest