Chassisshow - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

chassisShow

Displays all Field Replaceable Units (FRUs).
Synopsis
chassisShow
Availability
All users.
Release
V4.1.x
Description
Use this command to inventory and display the field replaceable unit (FRU)
header content for each object in the chassis. On some platforms for certain FRU
types, a few items may not be available. In these cases the lines will be
suppressed. Possibly affected are lines 2, 3, 4, 5, 6, 8, and 10 through 13. In
addition, for lines 10 through 13, if there is no data set, these lines will be
suppressed.
The header data is formatted into a record consisting of (up to) 13 lines. The lines
and their meaning are described below:
1. The first line of each record contains the object ID:
2. This line displays the FRU header version number:
Fabric OS Version 3.1.x/4.1.x Reference Guide
Object type:
Object number:
If the FRU is part of an assembly, a brief description in parentheses will be
displayed.
Header Version:
CHASSIS, FAN, POWER SUPPLY, SW BLADE
(switch), CP BLADE (control processor), WWN
(World Wide Name), or UNKNOWN; and
Slot <nn> (for blades), Unit <nn> (for
everything else).
<x>
chassisShow