Example
To initiate a system verification test on all switches in the fabric:
switch:admin> systemverification -short
systemverification: Setting parameters for short run.
systemverification: burnin parameters.
CURRENT - KEYWORD
1
- number_of_runs
2
- vib
10
- thermal
SYSTEMVERIFICATION
2
- min_lb_mode
1
- tbr_passes
1
- prt_on
1
- cntmem_on
1
- cmi_on
1
- retention_on
1
- cam_on
1
- flt_passes
1
- sta_passes
1
- plb_nframes
1
- txd_nframes
1
- xpt_nframes
1
- bpt_nframes
1
- slk_nmegs
1
- bpt_all_nframes
1
- slk_all_nmegs : 50
systemverification: Arming the burnin run on switch 0.
systemverification: Starting burnin on Switch 0
systemverification: Monitoring progress of the burnin activity.
systemverification: Outputting Status
State
COMPLETED
Errors
Each diagnostic test in this suit may report its own set of error messages when it
detects failures. See DIAGNOSTICS section of individual diagnostic test help
pages. These messages are only available in the log file.
See Also
burninerrclear
burninstatus
diagsetburnin
diagsetcycle
Fabric OS Version 3.1.x/4.1.x Reference Guide
: DEFAULT
: 1
: 2
: 10
- label : BURNIN
: 2
: 1
: 1
: 1
: 1
: 1
: 1
: 50
: 25
: 100
: 50
: 200
: 20
: 50
: 30
Status
Run
PASS
1
Cmd
TotCmds Script
22
22
switchburnin.sh
systemverification