Fabric OS Commands

perfAddUserMonitor

Add a user-defined filter-based monitor.
Synopsis: V3.1.x
perfAddUserMonitor portnumber, "grouplist"[,"alias"]
Synopsis: V4.1.x
perfAddUserMonitor [slotnumber/]portnumber,
"grouplist"[,"alias"]
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to define a special mechanism to qualify frames for statistics
gathering to fit your own special need.
Each group of elements with same offset will have their comparison result
(OR-ed) together before the combined result of each group get (AND-ed) together
for final comparison result. If the final result is logic 1, then the monitor counter
will be increased by one.
After a successful execution of this command, a monitor number is displayed. The
monitor number is provided for easy manipulation of these filter-based
performance monitors. The optional user-defined alias is also displayed if one was
specified. All valid monitor numbers and user-defined aliases can be retrieved
with the perfShowFilterMonitor command.
The maximum number of filters is 8 per port including user defined filters, read
filters, write filters, and read/write filters. In addition there should be no more than
6 different Offsets for each filter and no more than 4 different values per Offset
defined by user.