HP StorageWorks MSA 2/8 - SAN Switch Reference Manual page 621

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Only one frame is transmitted and received at any one time. The port LEDs flicker
green while the test is running.
The following port types are supported:
This command will not run on any other port type.
The command performs the following actions:
1. Initiate tests on certain ports (porttest command)
2. Stop active tests on certain ports (stopporttest command)
3. Get the snapshot of the test result. (porttestshow command)
Once porttest is triggered, you can use stopporttest to stop the test.
See the stopporttest command for more information.
Once porttest is triggered, you can use stopporttest to stop the test.
Current progress of porttest can be viewed by running porttestshow.
See the porttestshow command for more information.
If the port type changes during porttest execution, the test will continue on a
given port as long as it is supported. If a request is made to test all possible ports
on a given switch, the command will start a new test using the new port type to
start the appropriate test.
Operands
This command has the following operands:
ports
(V3.1.x only)
Fabric OS Version 3.1.x/4.1.x Reference Guide
E_ports
F_ports. (Must support ELS ECHO)
L_ports
N->N Loopback ports
Specify the port to run the test on. If omitted, the test will
be executed on all possible ports. Default value is All
ports enable. Valid values are:
-1 All ports.
-2 All E_ports.
-3 All L_ports.
-4 All F_ports.
-5 All N->N Loopback ports.
This operand is optional.
porttest
621