Turboramtest - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands

turboRamTest

Turbo SRAM logic test for 2-Gbps ASICs.
Synopsis: V3.1.x
turboramtest [passcount]
Synopsis: V4.1.x
turboramtest [--slot number][-passcnt count][-ports
itemlist]
Availability
Admin
Release
V3.1.x and V4.1.x
Description
This command verifies the on-chip SRAM located in the 2-Gb ASIC using the
Turbo-Ram BIST circuitry. These same SRAMS are tested by portRegTest
and sramRetentionTest using PCI operations, but for this test the BIST
controller is able to perform the SRAM write and read operations at a much faster
rate. It is also able to test one SRAM in each quadrant of every chip in parallel.
The following RAMs/CAMs are tested using TurboRAM test logic:
866
TX Buffer List Descriptor RAM
TX Q Arb Loop FIFO RAM
Statistics RAM
ALPA Match RAM
External Unicast Routing Table RAM
Internal Unicast Routing Table RAM
Multicast Routing Table RAM
TX Buffer Link RAM
Fabric OS Version 3.1.x/4.1.x Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 3.1Storageworks fabric os 4.1

Table of Contents