Fabric OS Commands
filterTest
Frame Filter test.
Synopsis: V3.1.x
filterTest [passcnt]
Synopsis: V4.1.x
filtertest [-passcnt passcnt][-txports list][-scamoff
offset][-dcamoff offset][-fdefoff offset]
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to verify that the ASIC frame level filtering logic includes
every type of filter actions:
This command can be run on every port, and send the frame in internal loop back
mode. The filter test requires two different ports in same quadrant due to the fact
that the filter logic sits in transmitter port can not work if frame is sent directly
from the embedded port.
This command may not be executed on an operational switch. You must first
disable the switch using the switchdisable command.
288
FLTACT_LIST_A - action to handle the subgroup A based filtering
FLTACT_LIST_B - action to handle the subgroup B based filtering
FLTACT_FROZEN - action to handle the frame frozen process
FLTACT_DISCARD - action to discard frame
FLTACT_FORWARD - action to forward frame