HP StorageWorks MSA 2/8 - SAN Switch Reference Manual page 115

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

To show all zone configuration information:
switch:admin> cfgShow
Defined configuration:
cfg:
USA1
cfg:
USA_cfg Red_zone; Blue_zone
zone:
Blue_zone
1,1; array1; 1,2; array2
zone:
Red_zone
1,0; loop1
alias: array1
alias: array2
alias: loop1
Effective configuration:
cfg:
USA_cfg
zone:
Blue_zone
1,1
21:00:00:20:37:0c:76:8c
21:00:00:20:37:0c:71:02
1,2
21:00:00:20:37:0c:76:22
21:00:00:20:37:0c:76:28
zone:
Red_zone
1,0
21:00:00:20:37:0c:76:85
21:00:00:20:37:0c:71:df
To show only configuration names:
switch:admin> cfgshow *
cfg:
a_cfg1 zone1; zone2
cfg:
b_cfg2 zone1; zone2; zone3
switch:admin>
Fabric OS Version 3.1.x/4.1.x Reference Guide
Blue_zone
21:00:00:20:37:0c:76:8c; 21:00:00:20:37:0c:71:02
21:00:00:20:37:0c:76:22; 21:00:00:20:37:0c:76:28
21:00:00:20:37:0c:76:85; 21:00:00:20:37:0c:71:df
cfgShow
115

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 3.1Storageworks fabric os 4.1

Table of Contents