Table 7: Diagnostic Error Codes (Sheet 4 of 4)
Error Number
3846
3847
847
384F
385F
3870
3871
3874
Operands
For V3.1.x, none.
For V4.1.x, this command has the following operands:
-a
-p
Example
The following illustrates two entries in the error log:
switch:admin> errshow
Error 14
--------
0x304 (fabos): Jun 14 11:57:52
Switch: 0, Warning FW-STATUS_SWITCH, 3, Switch status changed from HEALTHY/OK
to Marginal/Warning
Type <CR> to continue, Q<CR> to stop:
Fabric OS Version 3.1.x/4.1.x Reference Guide
spinSilk
spinSilk
spinSilk
spinSilk
spinSilk
spinSilk
spinSilk
spinSilk
1.
V3.1.x only.
2.
V4.1.x only.
Displays messages from the active error log. This displays the
error log messages generated during the current run time cycle.
Displays messages from the persistent error log.
Test
DIAG-ERRSTAT (BADORD)
1
DIAG-ERRSTAT (DISCC3)
2
DIAG-ERRSTAT (DISCC3)
DIAG-INIT
DIAG-PORTDIED
DIAG-PORTABSENT
DIAG-XMIT
DIAG-PORTSTOPPED
errShow