Cmemretentiontest - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands

cmemRetentionTest

Test the data retention of the central memory SRAMs.
Synopsis: V3.1.x
cmemRetentionTest [passcount]
Synopsis: V4.1.x
cmemretentiontest [--slot number][-passcnt count][-datatype
type][-ports itemlist][-seed value]
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to verify data retention in the central memory SRAMs in the
ASIC.
The method used is to write a fill pattern to all SRAMs, wait 10 seconds, and then
read all SRAMs checking that data read should match data previously written.
Repeat using the inverted version of the pattern. The patterns used are as follows:
Note:
the switch using the switchDisable command.
132
1) 0xffffffff (and 0x00000000)
2) 0x55555555 (and 0xaaaaaaaa)
3) 0x33333333 (and 0xcccccccc)
4) 0x0f0f0f0f (and 0xf0f0f0f0)
5) QUAD_RAMP with a random seed value (and its invert)
This command may not be executed on an enabled switch. You must first disable
Fabric OS Version 3.1.x/4.1.x Reference Guide