Setesdmode - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands

setesdmode

Enable or disable ESD mode.
Synopsis
setesdmode [mode | -show]
Availability
Admin
Release
V4.1.x
Description
Use this command to enable or disable ESD mode. The mode is saved in
non-volatile memory and stays in that mode until the next execution of
setesdmode.
The mode becomes active as soon as this command is executed. It does not require
a reboot to take effect.
ESD mode, when enabled, modifies the behavior of the diagnostic test methods
and post scripts. The exact behavior varies but most commonly consists of
disabling the ports defined with diagsetports when spinsilk or other
functional tests are run for ESD or EMI testing purposes.
Operands
This command has the following operands:
mode
-show
If no operand is specified the current value is displayed.
748
Specify 1 to enable ESD mode, specify 0 to disable ESD mode.
This operand is optional.
Specify this operand to display the current mode setting. This
operand is optional.