haFailover

Forces the failover mechanism so that the Standby CP becomes the Active CP.
Synopsis
haFailover
Availability
Admin
Release
V4.1.x
Description
Use this command to force the failover mechanism to occur so that the Standby
CP becomes the Active CP. Because haFailover results in CP reboot, a
warning message and a confirmation are displayed. If the user answers positively,
then the failover takes place.
On a StorageWorks Core switch, when HA synchronization is enabled and the
CPs are in sync, if a failover is initiated, the port traffic light will not flash during
the failover, even while traffic is continuing to flow.
Operands
None.