sensorShow

Displays sensor readings.
Synopsis
sensorShow
Availability
All users.
Release
V3.1.x and V4.1.x
Description
Use this command to display the current temperature, fan and power supply
status, and readings from sensors located on the switch. The actual location of the
sensors varies depending on the switch type.
Using V4.1.x with the StorageWorks Core switch, the information returned with
sensorShow is specific to the logical switch you are logged into:
Operands
None.
Fabric OS Version 3.1.x/4.1.x Reference Guide
If you are logged into Logical switch 0, sensors 1 through 4 are for switch
blade slots 1 through 4, respectively. Sensors 5 and 6 are for the two CPs in
slots 5 and 6, respectively.
If you are logged into Logical switch 1, sensors 1 and 2 are for the two CPs in
slots 5 and 6, respectively. Sensors 3 through 6 are for switch blade slots 7
through 10, respectively.
If you are logged into the Active CP through the console port, you are
prompted to specify the logical switch this command is executed on. If you
log in to the Active CP through the Fabric OS shell, this command always
executes on the default switch (logical switch 0).
Regardless of logical switch, sensors 7 through 9 are for the three chassis fans,
left to right, and sensors 10 through 13 are for the four chassis power supplies,
bottom to top.