Operands
This command has the following operands:
slotnumber
(V4.1.x only)
portnumber
alias
Example
To add a SCSI Read monitor to blade 2 port 4:
switch:admin> perfAddReadMonitor 2/4, "SCSI_R"
SCSI Read filter monitor #2 added
switch:admin>
See Also
perfAddEEMonitor
perfAddIPMonitor
perfAddRWMonitor
perfAddSCSIMonitor
perfAddUserMonitor
perfAddWriteMonitor
Fabric OS Version 3.1.x/4.1.x Reference Guide
Specify the slot number for a StorageWorks Core switch.
For all other switches this operand is not required. The slot
number must be followed by a slash ( / ) and the port
number, so that each port is represented by both slot
number (1 through 4, or 7 through 10), and port number
(0 through 15).
The StorageWorks Core switch has a total of 1–10 slots.
Slot number 5 and 6 are control processor cards, and slot
1 through 4, and 7 through 10, are port cards. On each
port card, there are 16 ports counted from the bottom, 0 to
15.
Specify a port number. Valid values for port number vary
depending on the switch type. This operand is required.
Specify a name for this monitor. This character string can
be a maximum of 10 characters long and is truncated if
more characters are specified. This operand must be
enclosed in quotation marks. This operand is optional. The
default alias is SCSI READ.
perfAddReadMonitor