domain and area fields of the SID zeroed. If a miss is expected (when the walking
1 or walking 0 pattern is used) the original SID in the frame transmitted is
received unchanged.
Note:
the switch using the switchDisable command.
Operands
This command has the following operand:
passcnt
(V3.1.x only)
--slot number
(V4.1.x only)
-passcnt count
(V4.1.x only)
-txport itemlist
(V4.1.x only)
Example
To verify that Content Addressable Memory (CAM) is functioning correctly in
V3.1.x:
switch:admin> camtest
Running CAM Test .............. passed.
To verify that CAM is functioning correctly in V4.1.x:
switch:admin> camtest -txports 1/1
Running CAM Test ..............Test Complete: "camtest" Pass 1 of 1
Duration 0 hr, 0 min & 5 sec (0:0:5:14).
passed.
Fabric OS Version 3.1.x/4.1.x Reference Guide
This command may not be executed on an enabled switch. You must first disable
Specify the number of times to perform this test. The
default value is 1.
Specify the slot number that the diagnostic will operate
on. The ports specified will be relative to this slot
number. The default is set to 0 and is designed to
operate on fixed port count products.
Specify the number of times to perform this test. The
default value is 1.
Specify a list of blade ports to test. By default, all the
blade ports in the specified slot (--slot) will be used.
See the itemlist help pages for further details.
camTest
85