Operands
This command has the following operands:
slotnumber
(V4.1.x only)
portnumber
alias
Example
To add a SCSI Write command monitor to blade 2 port 4:
switch:admin> perfAddWriteMonitor 2/4, "SCSI_W"
SCSI Write filter monitor #0 added
switch:admin>
See Also
perfAddEEMonitor
perfAddIPMonitor
perfAddReadMonitor
perfAddRWMonitor
perfAddSCSIMonitor
perfAddUserMonitor
Fabric OS Version 3.1.x/4.1.x Reference Guide
Specify the slot number for a StorageWorks Core switch.
For all other switches this operand is not required. The slot
number must be followed by a slash ( / ) and the port
number, so that each port is represented by both slot
number (1 through 4, or 7 through 10), and port number
(0 through 15).
The StorageWorks Core switch has a total of 1–10 slots.
Slot number 5 and 6 are control processor cards, and slot
1 through 4, and 7 through 10, are port cards. On each
port card, there are 16 ports counted from the bottom, 0 to
15.
Specify a port number. Valid values for port number vary
depending on the switch type. This operand is required.
Specify a name for this monitor. This character string can
be a maximum of 10 characters long and is truncated if
more characters are specified. This operand must be
enclosed in quotation marks. This operand is optional. The
default alias is SCSI_Write.
perfAddWriteMonitor
491