Fabric OS Commands
Operands
This command has the following operands:
slotnumber
(V4.1.x only)
portnumber
mode
When no operands are specified, the command reports a list of ports that are
disabled from becoming E_Ports.
Example
To disable blade 2 port 3 from becoming an E_Port:
switch:admin> portCfgEport 2/3, 0
Committing configuration...done.
switch:admin> portCfgEport
Ports:
0
1
--------------------------------
-
-
See Also
portShow
switchShow
536
Specify the slot number for a StorageWorks Core switch.
For all other switches this operand is not required. The slot
number must be followed by a slash ( / ) and the port
number, so that each port is represented by both slot
number (1 through 4, or 7 through 10), and port number
(0 through 15).
The StorageWorks Core switch has a total of 1–10 slots.
Slot number 5 and 6 are control processor cards, and slot
1 through 4, and 7 through 10, are port cards. On each
port card, there are 16 ports counted from the bottom, 0 to
15.
Specify a port number. Valid values for port number vary
depending on the switch type. This operand is required.
Specify 1 to enable the port to become an E_Port. This is
the default port state. Specify 0 to disable the port from
becoming an E_Port. When the port_number operand is
present, this operand must also be present.
2
3
4
5
6
-
NO
-
-
-
7
-
Fabric OS Version 3.1.x/4.1.x Reference Guide