Diagclearerror - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

diagClearError

Clear the diag software flag to allow for retest.
Synopsis: V3.1.x
diagclearerror [port]
Synopsis: V4.1.x
diagclearerror [[-slot] slot][-switch switch] | -all
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to clear the diagnostic software flag that indicates whether a
port is BAD or OK. The current flag settings are displayed by using the
diagShow command. This command resets the flag to allow the bad port to be
retested; otherwise the test skips the port.
This command does not clear the error log entry. Instead, it generates the
following DIAG-CLEAR_ERR message for each port software flag cleared. For
example, the following message is for a sample message displayed in the error
cleared log when you clear and error for a port 3:
Fabric OS Version 3.1.x/4.1.x Reference Guide
0x10f9d560 (tShell): Apr 9 08:35:50
Error DIAG-CLEAR_ERR, 3,
Pt13 (Lm3) Diagnostics Error Cleared
Err# 0001
diagClearError
179