HP StorageWorks MSA 2/8 - SAN Switch Reference Manual page 604

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands
Table 15: PortShow Display Fields (Continued)
portPhys
portScn
portId
portWwn
Distance
Speed
Interrupts
Unknown
Lli
Proc_rqrd
Timed_out
Rx_flushed
Tx_unavail
Free_buffer
Overrun
Suspended
604
Field
Port physical state:
No_Card - No interface card present
No_Module - No module (SFP or other) present
No_Light - Module not receiving light
No_Sync - Receiving light but out of sync
In_Sync - Receiving light and in sync
Laser_Flt - Module is signaling a laser fault
Port_Flt - Port marked faulty
Diag_Flt - Port failed diagnostics
Lock_Ref - Locking to the reference signal
Last state change notification for port.
24-bit D_ID for port.
Port WWNs of devices connected.
The port's long distance level.
The port's fixed speed level or negotiated speed level:
1 Gbps - Fixed speed of 1 Gb per second.
N1 Gbps - Negotiated speed of 1 Gb per second.
2 Gbps - Fixed speed of 2 Gb per second.
N2 Gbps - Negotiated speed of 2 Gb per second.
Negotiating - The speed of the port is being
determined.
Total number of interrupts.
Interrupts that are not counted elsewhere.
Low-level interface (physical state, primitive seqs).
Frames delivered for embedded N_Port processing.
Frames that have timed out.
Frames requiring translation.
Frames returned from an unavailable transmitter.
Free buffer available interrupts.
Buffer overrun interrupts.
Transmission suspended interrupts.
Description
Fabric OS Version 3.1.x/4.1.x Reference Guide

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storageworks fabric os 3.1Storageworks fabric os 4.1

Table of Contents