Perfcfgclear - HP StorageWorks MSA 2/8 - SAN Switch Reference Manual

Hp storageworks fabric os v3.1.x/4.1.x reference guide (aa-rs24c-te, june 2003)
Hide thumbs Also See for StorageWorks MSA 2/8 - SAN Switch:
Table of Contents

Advertisement

Fabric OS Commands

perfCfgClear

Clear the previously saved performance monitoring configuration settings from
non-volatile memory.
Synopsis
perfCfgClear
Availability
Admin
Release
V3.1.x and V4.1.x
Description
Use this command to clear the previously saved end-to-end and filter
configuration settings of performance monitoring from non-volatile memory.
Note:
Operands
None.
Example
To clear the performance monitoring information from non-volatile memory:
switch:admin> perfcfgClear
This will clear Performance Monitoring settings in FLASH ROM.
The RAM settings won't change. Do you want to continue? [y|n]y
Please wait ...
Committing configuration...done.
Performance Monitoring configuration cleared from FLASH.
switch:admin>
492
This command requires an Advanced Performance Monitoring license.
Fabric OS Version 3.1.x/4.1.x Reference Guide