Enabling the NQA
Client
Creating an NQA Test
Group
Configuring an NQA
Test Group
Configuring the
ICMP-echo Test
originated by the NQA client by listening to the packets from the specified
destination address and port number.
Follow these steps to configure the NQA server:
To do...
Enter system view
Enable the NQA server
Configure the UDP listening
function on the NQA server
Configurations on the NQA client take effect only when the NQA client is enabled.
Follow these steps to enable the NQA client:
To do...
Enter system view
Enable the NQA client
One test corresponds to one test group. You can configure test types after you
create a test group and enter the test group view.
Follow theses steps to create an NQA test group:
To do...
Enter system view
Create an NQA test group
and enter the NQA test group
view
n
If you execute the nqa entry command to enter test group view with test type
configured, you will enter test type view of the test group directly.
The ICMP test is used to test reachability of the destination host according to the
ICMP-echo reply or timeout information.
Follow these steps to configure the ICMP-echo test:
Use the command...
system-view
nqa server enable
nqa server { tcp-connect |
udp-echo } ip-address
port-number
Use the command...
system-view
nqa agent enable
Use the command...
system-view
nqa entry admin-name
operation-tag

Enabling the NQA Client

Remarks
-
Required
Disabled by default.
Required
The IP address and port
number must be consistent
with those configured on the
NQA client and must be
different from those of an
existing listening service.
Remarks
-
Required
Enabled by default.
Remarks
-
Required