Troubleshooting VoFR

Call Failure in
Huawei-Compatible
Mode

Poor VoFR Quality

ONFIGURATION
Symptom
Calls cannot be connected in Huawei-compatible mode
Analysis
In the Huawei-compatible mode, calls can be connected only when the frame
relay is normal, voice entities are configured correctly, and a sufficient bandwidth
is reserved for voice.
Solution
Use the display interface serial command to check that frame relay is
correctly configured on the two sides.
Check that the protocols of X.25 over frame relay work normally. You can use
the display fr pvc-info command to check the status of X.25 and LAPB or use
the display x25 vc command to check X.25 VC is congested.
Check that a voice bandwidth has been reserved for the corresponding DLCI.
Check that a frame relay class is configured for the DLCI and that a voice
bandwidth is configured for the frame relay class.
Check that the voice entities are properly configured.
Symptom
The VoFR quality is poor.
Analysis
A high VoFR quality requires sufficient bandwidth.
Solution
Check that the physical bandwidth of frame relay is sufficient (10 kbps in
accordance with G.729 and 9 kbps in accordance with G.723).
Check that a fragment size is configured for all DLCIs on the same interface
and that the fragment size is small enough. You can use the debugging fr
fragment interface serial command to view the packet fragment size.