Configuring Alarm Buzzer; Configuring Temperature Alarm Thresholds For A Card; Clearing The 16-Bit Interface Indexes Not Used In The Current System - 3Com MSR 50 Series Configuration Manual

3com msr 30-16: software guide
Hide thumbs Also See for MSR 50 Series:
Table of Contents

Advertisement

Configuring Alarm
Buzzer
n
Configuring
Temperature Alarm
Thresholds for a Card
Clearing the 16-bit
Interface Indexes Not
Used in the Current
System
You can enable the alarm buzzer function of the router. In this case, when the
temperature of the card on the router is higher than the upper threshold, the
buzzer sounds to notify you about the problem.
Follow these steps to configure the alarm buzzer function:
To do...
Enter system view
Configure alarm buzzer
This command is applicable on MSR 50 series routers only.
You can set temperature alarm thresholds for a card by using the following
command. When the temperature of a card exceeds the threshold, the device will
generate alarm signals.
Follow these steps to configure temperature alarm thresholds for a card:
To do...
Enter system view
Configure temperature alarm
thresholds for a card
In practical networks, the network management software requires the device to
provide a uniform, stable 16-bit interface index. That is, a one-to-one relationship
should be kept between the interface name and the interface index in the same
device.
For the purpose of the stability of an interface index, the system will save the
16-bit interface index when a card or logical interface is removed.
If you repeatedly insert and remove different subcards or interface cards to create
or delete a large amount of logical interface, the interface indexes will be used up,
which will result in interface creation failures. To avoid such a case, you can clear
all 16-bit interface indexes saved but not used in the current system in user view.
After the above operation,
For a re-created interface, the new interface index may not be consistent with
the original one.
For existing interfaces, their interface indexes remain unchanged.
Follow the step below to clear the 16-bit interface indexes not used in the current
system:
Configuring Device Management
Use the command...
system-view
buzzer enable
Use the command...
system-view
temperature-limit
slot-number lower-value
upper-value
2009
Remarks
-
Optional
Remarks
-
Optional
The temperature alarm
thresholds for a card vary with
devices by default.