Please Input the code of command to be excute(0-3): 0
Key Word:
Q(quit)
(00)trap
(01)owner
(02)<CR>
Please Input the code of command to be excute(0-2): 1
Key Word:
Q(quit)
(00)WORD
Please Input the code of command to be excute(0-0): 0
Please input a string:dlink (input Event owner)
Key Word:
Q(quit)
(00)trap
(01)<CR>
Please Input the code of command to be excute(0-1): 1
Will you excute it? (Y/N):y
After your configuring the RMON event, when the RMON alarm is induced, the evenLastTimeSent
region of the event item will be updated as the current sysUpTime firstly. If the event is configured with
log attribute, a message will be added into the log table; If the event is configured with trap attribute,
then a trap will be send while the group name is community. When the command "rmon event" is used
many times to configure the same index of event item, only the parameters of last time is available. You
can use the command "no rmon event index" to delete the event table whose index is index.
4.4.3 Configuring collection function of the RMON
RMON collection group is used to monitoring the statistic information of each port. The configuration
steps of RMON collection function are given below:
Command
cd config
interface iftype ifid
rmon collection stat
index [owner string]
cd..
cd..
write
[DEFAULT@Router /E1/1/]#rmon
Key Word:
U(undo)
D(default)
(00)collection
Please Input the code of command to be excute(0-0): 0
Key Word:
Q(quit)
(00)history
(01)stats
Please Input the code of command to be excute(0-1): 0
Key Word:
Q(quit)
(00)<1-65535>
Model Name
Generate SNMP trap when the event fires
Specify an owner for the event
Event owner
Generate SNMP trap when the event fires
Enter the global configurative mode
Enter the interface configurative mode
iftype is the type of the interface
ifid is ID of the interface
Enable the collection function of the interface
index is index of the collection items
owner string is used to describe some descriptive message of the
collection items
Back to global configurative mode
Back to management mode
Save the configuration
Q(quit)
Configure Remote Monitoring Collection on an interface
Configure history
Configure statistics
Set RMON statistics control index
- 52 -