D-Link DI-1750 Reference Manual page 207

Hide thumbs Also See for DI-1750:
Table of Contents

Advertisement

access-list-name offset
Key Word:
Q(quit)
(15)interface interface configuration
(16)neighbor Specify a neighbor router
(17)network enable RIP on an IP network
(18)no negate configuration
(19)offset Add offset for RIP routes
(21)redistribute Redistribute information from another protocol
(22)resume Resume an active outgoing network connection
Please Input the code of command to be excute(0-29): 19 (Select offset option )
(00)*
(01)interface-name
Please Input the code of command to be excute(0-1): 1(Select interface-name)
Please input a interface name:
input interface type and number,prompt is as below:
(00)in
(01)out
Please Input the code of command to be excute(0-1):
input 0,Select inbound,input 1,Select outbound,then prompt is as below:
(00)WORD
Please Input the code of command to be excute(0-0): 0
input 0,Select WORD option ,prompt is as below:
Please input a string:word( input string )
(00)<0-16>
Please Input the code of command to be excute(0-0): 0
Please input a digital number:Please input a string:2(input offset)
6.9.5 Adjust Timers
Routing protocols use several timers that determine such variables as the frequency of routing updates,
the length of time before a route becomes invalid, and other parameters. You can adjust these timers to
tune routing protocol performance to better suit your internetwork needs.
It also is possible to tune the IP routing support in the software to enable faster convergence of the
various IP routing algorithms, and, hence, quicker fallback to redundant routers. The total effect is to
minimize disruptions to end users of the network in situations where quick recovery is essential. To
adjust the timers, use the following commands in router configuration mode:
timers holddown value
timers expire value
timers update value
Take the first command for an example.:
In the prompt select timers option ,prompt is as below:
(00)holddown
(01)expire
(02)update
Please Input the code of command to be excute(0-2): 0
input 0,Select holddown option ,prompt is as below:
(00)<1-4294967295>
Please Input the code of command to be excute(0-0): 0
Please input a digital number:Please input a string:5(input time value)
All interface
adding offset for incoming routing updates
adding offset for outgoing routing updates
Name of IP access list
Offset
Command
holddown interval
expire interval
interval of routing updates
interval(in second)
Model Name
Function
How long (Unit: second) to delete a route from route
table.
How long (Unit: second) the route to be advertised as
invalidation.
Transmit the frequency of route update (interval of
transmit update, unit: second)
- 205 -