Lexmark X940e Service Manual page 146

Hide thumbs Also See for X940e:
Table of Contents

Advertisement

7510
Error code or
message
950.30 through
950.60
Service
NVRAM
mismatch
951.XX
Service
NVRAM failure
952.XX
Service NV
failure
953.XX
Service
NVRAM failure
954.XX
Service
NVRAM failure
955.XX
Service Code
CRC
956.00
Service system
board
956.01
Service system
board
2-32
Service Manual
Error contents
EPROM mismatch failure
RIP card assembly NVRAM
failure
Interconnect card assembly
NVRAM CRC failure
Operator panel assembly
NVRAM failure
Interconnect card assembly
NVRAM failure
RIP card assembly NAND
CRC failure
RIP card assembly processor
failure
RIP card assembly processor
over temperature failure
Description/Action
This error code indicates a mismatch between the
RIP card assembly and the interconnect card
assembly.
Warning: In the event of replacement of any one of
the following components:
• RIP card assembly
• Interconnect card assembly
Only replace one component at a time. Replace the
required component, and perform a POR before
replacing a second component listed above. If this
procedure is not followed, the printer will be
rendered inoperable. Never replace two or more of
the components listed above without a POR after
installing each one, or the printer will be rendered
inoperable.
Warning: Never install and remove components
listed above as a method of troubleshooting
components. Once a component has been installed
in a machine, it cannot be used in another machine.
It must be returned to the manufacturer.
Go to Go to
"950.30 through 950.60 EPROM
mismatch failure" on page
A failure has occurred in the RIP card asm NVRAM.
"951.XX RIP card assembly NVRAM
Go to Go to
failure" on page
2-174.
A recoverable NVRAM Cyclic redundancy check
(CRC) error occurred.
"952.XX Interconnect card assembly
Go to Go to
NVRAM CRC failure" on page
NVRAM chip failure with operator panel assembly
(mirror).
"953.XX Operator panel assembly
Go to Go to
NVRAM failure" on page
NVRAM chip failure with interconnect card
assembly.
"954.XX Interconnect card assembly
Go to Go to
NVRAM failure" on page
The code ROM or NAND flash failed the cyclic
redundancy check.
"955.XX RIP card assembly NAND
Go to Go to
CRC failure" on page
2-176.
The RIP card processor has failed.
Go to Go to
"956.00 RIP card assembly
processor failure" on page
The RIP card assembly has exceeded safe
operating temperature.
Go to Go to
"956.01 RIP card assembly
processor over temperature failure" on
page
2-176.
2-173.
2-174.
2-175.
2-175.
2-176.

Advertisement

Table of Contents
loading

This manual is also suitable for:

7510X945e

Table of Contents