6.6.8 ArrayLOC Troubleshooting Tree Continued - Array Color Setup

Troubleshooting ArrayLOC -
START HERE
Go to the Main > Configuration (4) > ArrayLOC (13) >
Bright/ColorLOC Configuration (3) menu.
Select the Array Status menu item to display the
Bright/ColorLOC Array Status.
Do the colors and brightness of
the array projectors match?
Yes
Is the array brightness the
expected brightness?
Yes
Are the array colors (red, green,
blue, white) the expected colors?

Entero RPMWU/RPMSP/RPMHD-LED01 User Manual

020-100367-05 Rev.1 (06-2012)
A3
B4
C7 C8 C9
B1
C3 C12
Menu
Reference
A11
A7
A1
No
B1
No
A8
C1
No
C1
Proceed to Take
Control of the Array/
Set the Array Color
No
Target Gamut
Target (Managing
Colors with ArrayLOC
in Section 3)
Bright/ColorLOC Array Status
4
< Target
Flags
ProjID Group Int
W
1
r wW*
0
W
2
gbW
3
Menu > Configuration > ArrayLOC > Projector Color Adjustment
Menu > Configuration > ArrayLOC > Array Color Target
Menu > Configuration > ArrayLOC > ArrayLOC Configuration
B2
A12
Menu > Configuration > ArrayLOC > Bright/ColorLOC Configuration
Menu > Configuration > Service
C11
Is the problem projector
Yes
Color Saturation > Select Color Adjustment
set to Max Drives?
No
C10
Yes
Is the problem projector
C5
Advanced Color Adjustment > Color Mode
set to Native?
the problem projector resolve
No
C9
No
Does clearing the very large
PCA adjustments resolve the
Yes
problem?
Yes
4 C12
C8
Yes
Do the mismatched projectors
Does any projector have very
change brightness when another
No
large PCA adjustments to their
projector takes control of the array and
primary colors?
changes the RGB Brightness Target?
A4
No
C7
C2
Note!
Are there any projectors
For "Maximum"-type
with very different color
Yes
Target Gamuts the Common
capabilities than the others?
Gamut should be close to the
listed projector capabilities
rather than the Target Gamut.
C2
No
Is the
Is the Common Gamut
Yes
reasonably close to the
Yes
correct?
Target Gamut?
Target Gamut
800 330
160 800
125 000
313
329
1000
Common Gamut
687 306
193 738
150 34
313 329
Age
Rx
Ry
RY
Gx Gy
GY
Bx
By
BY
Wx Wy
211
1
1
692 304 283.2 185 748 696.8 139 28
67.2
313 329
369.1
211
1
1
687 306 109.9 193 741 123.4 145 23
17.9
313 329
361.2
211
1
1
699 296 416.5 188 745 778.5 141 29
91.7
313 329
418.0
211
1
1
700 295 343.7 181 749 700.9 149 23
57.3
313 329
390.5
A5
Menu > Status
C11
Menu > Configuration > Service > Color Saturation
C10
Menu > Configuration > Service > Advanced Color Adjustment
A13
A14
C4
Menu > Configuration > Service > ArrayLOC Service
Done
C6
Recalibrate the internal
sensor of the problem
projectors
Does cycling AC power to the
Yes
No
array resolve the problem?
OR
Call Tech Support
Yes
No
Does cycling AC power to
the problem?
Proceed to Fine
Tuning of Projected
Colors (Managing
Colors with ArrayLOC
A14
No
in Section 3)
C4
Is the Adjustment
Interval set to an
Yes
appropriate value?
No
No
Yes
C3
Menu
> Configuration
Do the mismatched projectors
> ArrayLOC
change color when another projector
> Array Color
takes control of the array and
Target
changes the Array Color Target?
350
WY
Section 6: Troubleshooting Tree
6-11

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents