Appendix D: Serial Command Reference
(BBL) BOTTOM BLANKING (Cont'd)
MAIN
PIIP
EXAMPLES:
(BBL 40) - Set bottom blanking to 40 on main video.
(BBL+MAIN 40) - Set bottom blanking to 40 on main video.
(BBL+PIIP 40) - Set bottom blanking to 40 on PIP video.
(BBL+IN32 40) - Set bottom blanking to 40 on Slot 3 Input 2.
(BBL?) - Returns the bottom blanking value on main video.
(BBL+PIIP?) - Returns the bottom blanking value on PIP video.
(BBL+IN12?) - Returns the bottom blanking value on Slot 1 Input 2.
(BDR) BAUD RATE
CONTROL GROUP:
DESCRIPTION
Set the baud rate for a serial communications port. For RS-232 IN and RS-232 OUT, the default is 115200. For
RS-422, the default is 19200. The default communications settings for all ports is 8 data bits, no parity. Valid baud
rates, with the values to select them, are:
0 = 1200
1 = 2400
2 = 9600
3 = 19200
SUBCODE
PRTA
PRTB
PRTC
EXAMPLES:
(BDR+PRTA 6) - Set baud rate on port A to 115200 bits per second.
(BDR+PRTA?) - Get baud rate (BDR+PRTA!"115200").
D-10
Preference
SUBCLASS:
4 = 38400
5 = 57600
6 = 115200
Set the bottom blanking for the main image.
Set the bottom blanking for the PIP image.
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Set the baud rate on port A (RS-232 IN).
Set the baud rate on port B (RS-232 OUT).
Set the baud rate on port C (RS-422).