(GID) VIDEO DECODER GROUNDED INPUT SELECTION
CONTROL GROUP:
DESCRIPTION
Set the Input signal grounding method to single-ended or differential. Valid values are:
0 = Differential (default)
1 = Single-ended
SUBCODE
SLxy
EXAMPLES:
(GID+SL31 1) - Set grounding on Slot 3, Input 1 to single-ended.
(GID+SL16 ?) - Returns the current grounding method of Slot 1, Input 6.
(GIO) GENERAL PURPOSE INPUT/OUTPUT
CONTROL GROUP:
DESCRIPTION
Control or monitor the state of the General Purpose Inputs and Outputs.
The strings have one character for each hardware connector pin, and from left to right, correspond to the pin
numbers 2,3,4,6,7,8,9. (Pin 1 is 12V and Pin 5 is Ground - they cannot be read, set or configured).
A low state (or value of 0) will be read on an Input pin if the circuit attached to the pin is open. A high state (or
value of 1) will be read on an Input pin if the circuit attached to the pin is shorted to ground. This corresponds to a
switch closing event.
SUBCODE
CNFG
STAT
EXAMPLES:
(GIO+STAT?) - Get status of all the Inputs. Returns (GIO+STAT!"0000000") - All Inputs are low.
(GIO+STAT "1x01000") - Set status of the GPOs - 2 high, 3 no change, 4 Low, 6 High, 7 Low, 8 Low, 9 Low.
(GIO+STAT "hxxlxxx" 500) - Set status of the GPOs - 2 Pulse high, 6 Pulse Low. Use interval of 500 ms for each.
(GIO+CNFG "IIOOOIO") - Set pins 2, 3 and 8 to Input, 4, 6, 7 and 9 to Output.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Option
Power Up
SUBCLASS:
Config
Power Down
SUBCLASS:
Appendix D: Serial Command Reference
ACCESS LEVEL:
DESCRIPTION OF USE
Set the Input signal grounding method for the specified Slot
and Input.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the Direction for the individual pins to Inputs or outputs.
Get the state of all Inputs, or set the state of all outputs.
Operator
Advanced
D-31

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents