Appendix D: Serial Command Reference
(ACT) ACTIVE WINDOW
CONTROL GROUP
DESCRIPTION
This control defines the Input active window in pixels. The production aperture is available for analog sources
only, but not for decoded analog signals. The aperture is set once on every auto setup or on new signal detection
when a channel for that signal is not present. The aperture defines the maximum window in which blanking
controls can be opened up to, relative to the active portion of the signal. This is a read only control.
SUBCODE
INxy
MAIN
PIIP
EXAMPLES:
(ACT?) - Returns the active window for main video.
(ACT+PIIP?) - Returns the active window for PIP video.
(ACT+IN12?) - Returns the active window for Slot 1 Input 2.
(ADR) ADDRESS
CONTROL GROUP
DESCRIPTION
Set/Query Device Address on ASCII Protocol network. Required only for RS-232 connections that are daisy
chained to allow directed messages.
SUBCODE
<No Subcode >
EXAMPLES:
(65535 ADR 0) - Set all devices to address 0.
(0 ADR 5) - Set first device at address 0 to address to 5.
(65535 1001ADR?) - Query address for all devices and return results to address 1001.
Expected response to previous query (01001 00005ADR!005).
(AGC) AUTOMATIC GAIN CONTROL
CONTROL GROUP:
DESCRIPTION
Enable/disable the Automatic Gain Control. This control allows the decoder to automatically track the sync
amplitude of the incoming signal. Turn this control OFF if you are experiencing strange color artifacts, indicating
an incompatibility between the source and the AGC.
SUBCODE
INxy
D-4
Input
SUBCLASS
:
:
Preference
SUBCLASS
:
Input
Power Down
SUBCLASS:
Power Down
ACCESS LEVEL
DESCRIPTION OF USE
Set the adaptive contrast for Slot x, Input y.
Set the adaptive contrast for main video.
Set the adaptive contrast for PIP video.
Power Down
:
DESCRIPTION OF USE
Valid Address range is 0 to 999. Reserved broadcast address is
65535.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the AGC on Slot x, Input y to the specified state of either
enable or disable.