(LBL) LEFT BLANKING (Cont'd)
SUBCODE
INxy
MAIN
PIIP
EXAMPLES:
(LBL 40) - Set left blanking to 40 on Main video.
(LBL+MAIN 40) - Set left blanking to 40 on main video.
(LBL+PIIP 40) - Set left blanking to 40 on PIP video.
(LBL+IN32 40) - Set left blanking to 40 on Slot 3, Input 2.
(LBL?) - Returns the left blanking value on main video.
(LBL+PIIP?) - Returns the left blanking value on PIP video.
(LBL+IN12?) - Returns the left blanking value on Slot 1, Input 2.
(LDT) LEVEL DETECTOR
CONTROL GROUP:
DESCRIPTION
This Level Detector control changes the gamma table settings to make it easy for the user to adjust the Input
levels. It causes the data to be processed so that all levels below a specified value are set to black (0) and all above
and including it are set to white (1024). This control takes place before the scaler/deinterlacer.
SUBCODE
<No Subcode >
EXAMPLES:
(LDT 1) - Turn on level detector.
(LDT 0) - Turn off level detector.
(LDV) LEVEL DETECTOR VALUE
CONTROL GROUP:
DESCRIPTION
The Level Value control specifies the value to be used by the level detector. The range is 1-1023. This control
takes place before the scaler/deinterlacer.
SUBCODE
<No Subcode >
EXAMPLE:
(LDV 500) - Set level detector to 500. All data greater than or equal to 500 will be shown in the image.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Unsaved
SUBCLASS:
Unsaved
SUBCLASS:
DESCRIPTION OF USE
Set the left blanking for Slot x, Input y.
Set the left blanking for the Main image.
Set the left blanking for the PIP image.
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Appendix D: Serial Command Reference
Operator
Operator
D-39

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents