Christie Entero RPMWU User Manual page 170

Table of Contents

Advertisement

Appendix D: Serial Command Reference
(INM) CHANNEL 'IN MENU'
CONTROL GROUP:
DESCRIPTION
Determine whether the channel should be visible in the Channel List, which is available by pressing the 'Channel'
key on the remote's keypad.
SUBCODE
C0xx
MAIN
PIIP
EXAMPLES:
(INM?) - Get channel in-menu state for channel used by main.
(INM+MAIN?) - Get channel in-menu state for channel used by main.
(INM+PIIP?) - Get channel in-menu state for channel used by PIP.
(INM 1) - Show in-menu for the channel being used by main.
(INM+PIIP 1) - Show in-menu for the channel being used by PIP.
(INM+MAIN 0) - Hide in-menu for the channel being used by main.
(INM+C001 0) - Hide in-menu for channel 1.
(ITG) TEST PATTERN GREY
CONTROL GROUP:
DESCRIPTION
Specify the grey level to use for the 'Grey' flat field internal test pattern. Range 0-1023. The level defaults to 512
on power up. This command is on available while the grey test pattern is being displayed.
SUBCODE
<No Subcode >
EXAMPLE:
(ITG 512) - Set test pattern grey to mid point.
D-36
Channel
SUBCLASS:
Unsaved
SUBCLASS:
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Toggle In Menu for channel (xx=channel number from 01 to
99).
Toggle In Menu for the channel being used by main.
Toggle In Menu for the channel being used by PIP.
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Operator
Operator
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1 (6-2012)