Appendix D: Serial Command Reference
(EME) ERROR MESSAGE ENABLE
CONTROL GROUP:
DESCRIPTION
This control enables the displaying of error messages, and determines to which interface the messages are sent.
Error messages can be turned off or can be displayed on the screen, sent out the serial port, or both. This setting
does not affect messages for invalid user entries, for which error messages are always displayed. Valid values are:
0 = Off
1 = Screen
2 = Serial ports
3 = All
SUBCODE
<No Subcode >
EXAMPLES:
(EME ?) - Get current Error Message Enable state.
(EME 1) - Direct error messages to the screen.
(ESM) EM STEALTH MODE
CONTROL GROUP:
DESCRIPTION
Stealth mode extinguishes LEDs on the Electronics Module. Typically this is used in simulation environments
where extraneous light would detract from the scenario (when the scene involves IR).
SUBCODE
<No Subcode >
EXAMPLES:
(ESM 1) - Enable EM stealth mode.
(ESM ?) - Report the stealth mode value.
(FAD) FADE TIME
CONTROL GROUP:
DESCRIPTION
Controls the amount of time it takes to fade between images on a source switch. It also fades in the PIP and OSD
if possible.
SUBCODE
<No Subcode >
EXAMPLE:
(FAD 100) - Fade for 1 second.
D-26
Preference
SUBCLASS:
Preference
SUBCLASS:
Preference
SUBCLASS:
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Time in hundredths of a second to allow the fade. Range 0 -
150 where 150 = 1.5 seconds, 1 = 10ms, 0 = off.
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
Operator
Operator
Operator
020-100367-05 Rev. 1 (6-2012)

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents