Christie Entero RPMWU User Manual page 196

Table of Contents

Advertisement

Appendix D: Serial Command Reference
(SMP) SAMPLING MODE (Cont'd)
MAIN
PIIP
EXAMPLES:
(SMP 1) - Set sampling mode to YCbCr422 on main video.
(SMP+MAIN 0) - Set sampling mode to YCbCr444 on main video.
(SMP+PIIP 1) - Set sampling mode to YCbCr422 on PIP video.
(SMP+IN32 1) - Set sampling mode to YCbCr422 on Slot 3, Input 2.
(SMP?) - Returns the current sampling mode value on main video.
(SMP+PIIP?) - Returns the current sampling mode value on PIP video.
(SMP+IN12?) - Returns the current sampling mode value on Slot 1, Input 2.
(SOR) SCREEN ORIENTATION
CONTROL GROUP:
DESCRIPTION
Selects the orientation of the displayed image. It can be displayed normally, inverted horizontally, inverted
vertically, or inverted in both directions, as required by the projector installation. Valid values are:
0 = Front Projection
1 = Rear Projection
2 = Front Projection Inverted
3 = Rear Projection Inverted
SUBCODE
<No Subcode >
EXAMPLE:
(SOR 0) - Set image orientation to Front projection.
(SPS) SPLASH SCREEN
CONTROL GROUP:
DESCRIPTION
Upload a User Splash Screen (logo) bitmap and configure splash screen display options.
D-62
Preference
SUBCLASS:
Preference
SUBCLASS:
Set the sampling mode on main video.
Set the sampling mode on PIP video.
Power Up
ACCESS LEVEL:
DESCRIPTION OF USE
Power Up
ACCESS LEVEL:
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
Operator
Operator
020-100367-05 Rev. 1 (6-2012)