Christie Entero RPMWU User Manual page 143

Table of Contents

Advertisement

(ASU) AUTO SETUP
CONTROL GROUP:
DESCRIPTION
This control tells the projector to automatically adjust as many parameters as it can to produce the optimal setup
for the current input.
NOTE: If main and PIP video are using the same channel, the Auto Setup will act on both, regardless of the sub-
code being used.
In some cases for analog video, the user can select the format that best suits their source. This selection helps the
Auto Setup get the correct settings for the tracking and phase controls for analog sources that contain the same
number of active lines, but have a different aspect ratios.
• All digital and decoder option cards do not allow options for auto setup since digital hardware provides
enough information to perform the correct auto setup.
• Analog PC graphics sources (4/5-wire sync) present a list of formats based on the current active lines detected
in the video.
• Analog Video Sources (3 wire sync on green) always have the options 'Default' and 'Advanced'. Video
sources use a look up table to determine their format based on video standards. The 'Advanced' Auto Setup
selection measures the start pixel and start line whereas 'Default' uses the table values as is.
SUBCODE
MAIN
PIIP
EXAMPLES:
(ASU) - Perform standard Auto Setup on main video.
(ASU+MAIN) - Perform standard Auto Setup on main video.
(ASU+PIIP) - Perform standard Auto Setup on PIP.
(BBL) BOTTOM BLANKING
CONTROL GROUP:
DESCRIPTION
Set the number of lines to blank (turn to black) at the bottom of the image. This can be used to blank out any
unwanted data near the bottom edge of the image.
A positive amount of blanking makes the image smaller. A negative amount of blanking makes the image larger.
Negative blanking is only applicable to analog signals, when the Auto Setup has not been able to set the image
size correctly. It is preferable not to use negative blanking, but to run Auto Setup again, ensuring that the content
has active pixels on each edge of the image.
The maximum amount of bottom blanking allowed is half the image height minus 10. For negative blanking, the
image size can only be increased to the limit of the sync.
SUBCODE
INxy
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(6-2012)
Unsaved
SUBCLASS:
Input
Power Down
SUBCLASS:
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Perform a standard Auto Setup on the main video.
Perform a standard Auto Setup on the picture-in-picture (PIP)
video.
ACCESS LEVEL:
DESCRIPTION OF USE
Set the bottom blanking for Slot X, Input Y.
Appendix D: Serial Command Reference
Operator
Operator
D-9