Preventative Maintenance - Christie Entero RPMWU User Manual

Table of Contents

Advertisement

5.2.6 Preventative Maintenance

LED output with certain optical instruments (for example, eye loupes, magnifiers and
microscopes) within a distance of 100 mm may pose an eye hazard.
Table 5.1 Preventative Maintenance
Part Description
Projection Lens
Projection Lens
External Projector Covers
ASSY Dual Fan Pack EM
(P/N: 003-002138-xx)
ASSY Dual Fan Pack
PHM
(P/N: 003-002676-xx)
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
020-100367-05 Rev. 1(06-2012)
The projector is a class 2M source of visible LED radiation. Directly viewing the
Frequency
As required
Clean: A small amount of dust on the lens has very little effect on picture
quality. Clean only if absolutely necessary.
Dust: Brush most of the dust from the lens with a camel-hair brush or blow
dust away with a dust-free blower.
As required
Fingerprints, smudges or oil:
Do not use a cleaning solvent that contains ammonia. Avoid lens contact
with Xylene and Ether.
As required
Clean: Clean dust from external covers using a clean, lint-free cotton cloth
as required.
NOTE: Before cleaning the modules, it is recommended that you install the
lens cap. This will keep dust particles from settling on the glass surface of
the lens.
Every 5 years
Remove and replace. Refer to the Entero RPMWU/RPMSP/RPMHD-
or 45,000
LED01 Service Manual (P/N 020-100368-04) for complete replacement
hours, which-
instructions.
ever comes
first
Action
1.
Fold a microfibre cloth smooth and gently wipe remaining dust
particles from the lens. Wipe evenly with the smooth portion of
the cloth that has no folds or creases. DO NOT apply pressure
with your fingers - use the tension in the folded cloth itself to
collect dust.
2.
If significant dust is still bound to the surface, dampen a clean
microfibre cloth with coated optics cleaning solution (damp,
not dripping). Wipe gently until clean.
1.
Brush away most of the dust with a camel-hair brush and/or
blow away using a dust-free blower.
2.
Roll a lens tissue around a swab and soak it in coated optics
cleaning solution. Tissue should be damp, but not dripping.
3.
Gently wipe the surface using a figure-8 motion. Repeat this
motion until the blemish is removed.
Section 5: Maintenance
5-3