Appendix D: Serial Command Reference
(KEN) KEYPAD IR SENSOR DISABLE
CONTROL GROUP:
DESCRIPTION
Enable or disable the IR or wired keypad sensors. You cannot disable the keypad that is currently being used.
SUBCODE
FRNT
WIRE
EXAMPLES:
(KEN+FRNT 0) - Disable front IR sensor.
(KEN+WIRE?) - Get current wired jack enabled state.
(KEY) KEY CODE EMULATION
CONTROL GROUP:
DESCRIPTION
Use Key Codes to emulate button presses on the IR or wired keypads.
SUBCODE
<No Subcode >
EXAMPLES:
(KEY 46) - Send the Power key (Down/press).
(KEY 174) - Send the Power key (Up/release).
(KEY?) - View the last emulated key that was sent.
(LBL) LEFT BLANKING
CONTROL GROUP:
DESCRIPTION
Set the number of lines to blank (turn to black) at the left of the image. This can be used to blank out any unwanted
data near the left edge of the image.
A positive amount of blanking makes the image smaller. A negative amount of blanking makes the image larger.
Negative blanking is only applicable to analog signals, when the auto setup has not been able to set the image size
correctly. It is preferable not to use negative blanking, but to run auto setup again, ensuring that the content has
active pixels on each edge of the image.
The maximum amount of left blanking allowed is half the image width minus 10. For negative blanking, the
image size can only be increased to the limit of the sync.
D-38
Preference
SUBCLASS:
Unsaved
SUBCLASS:
Input
Power Down
SUBCLASS:
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
Set to 1 to enable the front IR keypad sensor, 0 to disable.
Set to 1 to enable the wired keypad jack, 0 to disable.
Power Down
ACCESS LEVEL:
DESCRIPTION OF USE
ACCESS LEVEL:
Entero RPMWU/RPMSP/RPMHD-LED01 User Manual
Operator
Operator
Operator
020-100367-05 Rev. 1 (6-2012)